1/2"NPT x G1.1/4" Pset=970psi PS = 165 bar - 2393 psi
Product use
Safety valve series 3030, 3060, 3061 3065, 3030E and 3061E, unbalanced conventional direct load. The valve opens when the thrust exerted on the plunger by the refrigerant under pressure, under calibrated conditions, overcomes the opposing force of the spring acting on the plunger. Safety accessories for use with refrigerant R744, belonging to Group 2 as defined in Article 13 of Directive 2014/68/EU. Calibration range: - from 9 to 50 bar for series 3030 and 3060 - from 11 to 60 bar for series 3061 and 3065 - from 60 to 150 bar for series 3030E and 3061E
Product Details
Connections IN
1/2" NPT
Connections OUT
1.1/4" G
Orifice section [mm²]
95
Orifice section [in.²]
0,147
ASME slope [mc/(min x bar)]
1,1
ASME slope [SCFM/psia]
2,68
Set pressure range [bar]
60 - 150
Set pressure range [psi] (1)
870 - 2176
PS [bar]
165
PS [psi]
2393
TS[°C] min.
-50
TS[°C] max.
+150
Package pcs
8
Notes where expressly stated
(1): data to be used in the construction of the part number